QUICK SELECTOR
 Advance Radiant Heat Technology 


 Sierra's Mother Bird Radiant Heat 
Sierra radiant heat brooders distribute a chick comfort zone compatible to a mother gamebird's natural environment, while maintaining the highest fuel efficiency.

The sierra 'Spooner Gamebird Brooder' environment management system once set for the incoming placement, provides controlled favourable conditions, eliminating the need for constant supervision or adjustment.

Not even dawn activity wing flap or airborne particles can degrade the performance
of the brooder to monitor and manage the litter floor environment.

The 'Spooner Gamebird Brooder' comfort zone will always provide a litter floor micro climate to facilitate even chick growth.

Specialising in space heating science fuelled by gas, Sierra's research embraces working game farm studies in the U.S.A., Canada, Europe and their U.K. home market. Such ongoing research studies with the support of the game industry are vital to advancing hatchery, brooding and rearing techniques.

Sierra's years of brooder manufacturing experience has
been invested in the GB2, 4 and 6 specially developed 'Spooner Gamebird' range.

A range of fully fail safe brooders robustly engineered and assembled from extremely tolerant use and abuse tough materials.

Designed to provide straight forward monitoring controls of pheasant, partridge, mallard and all type of avian birds with years of easy maintenance and reliable, economical operation.
 

BACK TO TOP

Spooner Brooder
(Why not fit a system for your next placement?)
for GAMEBIRD brooding
BACK TO TOP

Controls  
Picture of controller All models are available with two systems of temperature control:
The thermostat controlled system establishes a reliable and deicated automatic modulating temperature control for environmental heat needs. Once set, the temperature remains constant within a degree or two, avoiding the risk of bird chilling.

The ten-position manual gas regulator control provides the facility to complete the range of adjustments for environmental heating requirements. The gas regulator control can be fitted to a single gas cylinder or to a change over valve unit or into a gas line.
Where gamebird enterprise emphasis is proceessed product rather than leisure sport, individual brooder controls or planned fully automated computerised controlled systems are available.

All brooder models are fitted with a fail safe device.

BACK TO TOP

Technical and economical information
Model reference GB2 GB4 GB6
Pheasant numbers*
Partridge numbers*
Mallard numbers*
350/450
650/750
650/750
450/1000
750/1250
750/1250
600/1200
950/1450
950/1450
Heat input

Btu's


Kilowatts



max 9000
min 3000

max 2.6
min 0.26



max 13648
min 4090

max 4.0
min 0.4



max 19500
min 5850

max 5.71
min 0.57
Gas consumption

Propane per hour
Lbs


Litres


U.S.gallons

Natural per hour

cu/ft/hr


m³hr



max 0.42
min 0.19

max 0.37
min 0.17

max 0.098
min 0.033


max 9.00
min 3.00

max 0.25
min 0.08



max 0.59
min 0.26

max 0.54
min 0.24

max 0.149
min 0.045


max 13.64
min 4.09

max 0.36
min 0.11



max 0.87
min 0.40

max 0.77
min 0.35

max 0.213
min 0.064


max 19.50
min 5.85

max 0.52
min 0.16
Operating pressure

Propane Gas


Natural Gas


Inches W.G.
max 20/min 3

Inches W.G.
max 8/min 1.6


Millibars
max 50/min 10

Millibars
max 20/min 4.0